• Solids Control EquipmentMud Shale Shaker Degasser Mud Cleaner Centrifuge Mud Agitator Mud Gun Jet Mud Mixer Centrifugal Pump Shear Pump Spray Pump Vacuum Pump Mud Gas Separator Ignition Drilling Cuttings Dryer Filter Press Conveyor
  • Mud Treatment SystemDrilling Fluid Solids Control System Water-based Mud Treatment System Oil based Mud Treatment System Trenchless Mud Treatment System Mud Mixing System Drilling Fluid Cooling System Truck mounted Mud Circulation System Barite Recovery System
  • Tank and Steel StructureRig Mat Elevated Diesel Tank Nested Water Tank Fracturing Fluid Tank Drilling Pipe Basket Drill Cuttings Box Mud Storage Tank
  • Drilling Tools and Spare PartsMud Shale Shaker Spare Parts Centrifugal Pump Spare Parts Mud Pump Spare Parts Centrifuge Spare Parts Mud Tank Bottom Valve Mud Hopper Mud Tank Level Alarm Polyurethane Cyclone Electric Motor WPS Reducer Mud Tank Union Explosion-proof Water Tank Heater
  • ApplicationOilfield DrillingGas Geothermal DrillingTrenchless HDDDrilling Waste TreatmentSewage TreatmentTunnel ShieldTailings Dry Discharge
  • Contact us
    WhatsApp: 86-13735815206 / 86-17392256505
    WeChat: 86-13735815206 / 86-17392256505
    Phone: 86-29-88680837
    Mail: sales@hlsolidscontrol.com
    Add: Room 804, Building 1, Western Cloud Valley Phase II, Fengxi New Town, Xixian New District, Shaanxi Province

    Installation And Operation Manual Of Mud Agitator

    Time: 2024-08-06 Source: Author: HL Solidscontrol

    Installation And Operation Manual Of Mud Agitator

    Step 1: Fix the agitator base 4 corners firmly to tank surface.

    Step 2: Prepare sufficient gear lubricating oil (refer to the product manual for the lubricating oil model and amount).

    Step 3: Open the yellow oil filling hole cover on reducer, and insert oil funnel.

    Step 4: Fill the lubricating oil, make sure its level is above red dot, the center of the oil mark.

    Step 5: Screw on the oil filling hole cover and remove the small cone plug on the breather.

    Step 6: Turn on power, press the electric start button, and correct the impeller rotation direction.

    Step 7: Clean the inside of reducer and replace lubricating oil after the first 100 hours operation. Thereafter, repeat the cleaning and lubrication process every 2500 hours.

    Step 8: The temperature of reducer is not more than 95℃ in normal working. Please turn off power and let it cool down once high temperature.

    Step 9: Regularly check the connection of the elastic coupling. Tighten the nut of pin and replace the severely deformed or aged elastic sleeve timely.