• Solids Control EquipmentMud Shale Shaker Degasser Mud Cleaner Centrifuge Mud Agitator Mud Gun Jet Mud Mixer Centrifugal Pump Shear Pump Spray Pump Vacuum Pump Mud Gas Separator Ignition Drilling Cuttings Dryer Filter Press Conveyor
  • Mud Treatment SystemDrilling Fluid Solids Control System Water-based Mud Treatment System Oil based Mud Treatment System Trenchless Mud Treatment System Mud Mixing System Drilling Fluid Cooling System Truck mounted Mud Circulation System Barite Recovery System
  • Tank and Steel StructureRig Mat Elevated Diesel Tank Nested Water Tank Fracturing Fluid Tank Drilling Pipe Basket Drill Cuttings Box Mud Storage Tank
  • Drilling Tools and Spare PartsMud Shale Shaker Spare Parts Centrifugal Pump Spare Parts Mud Pump Spare Parts Centrifuge Spare Parts Mud Tank Bottom Valve Mud Hopper Mud Tank Level Alarm Polyurethane Cyclone Electric Motor WPS Reducer Mud Tank Union Explosion-proof Water Tank Heater
  • ApplicationOilfield DrillingGas Geothermal DrillingTrenchless HDDDrilling Waste TreatmentSewage TreatmentTunnel ShieldTailings Dry Discharge
  • Contact us
    WhatsApp: 86-13735815206 / 86-17392256505
    WeChat: 86-13735815206 / 86-17392256505
    Phone: 86-29-88680837
    Mail: sales@hlsolidscontrol.com
    Add: Room 804, Building 1, Western Cloud Valley Phase II, Fengxi New Town, Xixian New District, Shaanxi Province

    Operation Manual Of Diesel Ignition Device

    Time: 2024-08-06 Source: Author: HL Solidscontrol

    Operation Manual Of Diesel Ignition Device

    Step 1: Connect the gas circuit, oil circuit and electric circuit of the ignition device. Connect the high-voltage output of the control box to the wire reel, the wire reel to the high-voltage package, and the power input 220V to the charging port.

    Step 2: Test the sealing of the gas circuit and oil circuit, to ensure sealing well.

    Step 3: Inject diesel into the fuel tank, close the gas source valve, open the fuel tank drain valve, and evacuate personnel to a safe area.

    Step 4: Turn on the gas source valve, and then press the ignition button in the control box when the diesel is sprayed out. The Ignition completed successfully.

    Step 5: Turn off the power supply and gas source valve after the ignition is completed. Pay attention to the voltage of the control box, charge it in time once the voltage is lower than 12V.