Product details
The drilling fluid desilter is a three-stage solids control device used in the solid phase control system of the drilling fluid. It is a combination of a cyclone desilter and a vibrating screen, also can be supplied without the underflow screens according to customer's request.
The mud desilter usually use 4" and 5" desilter cyclones, which is mainly used to separate solid particles with a particle size of 15-44 microns in the drilling fluid. HCN series desilter is one of the important equipment to stabilize and adjust the technical indicators of drilling fluid. >>Send an Enquiry sales@hlsolidscontrol.com<<
Technical parameters of mud desilter >>Send an Enquiry sales@hlsolidscontrol.com<<
Model |
HCN100x4S |
HCN100xS |
HCN100x10S |
HCN100x16S |
Capacity |
50 m3/h |
100 m3/h |
160 m3/h |
200 m3/h |
Cyclone Diameter |
100mm(4") |
100mm(4") |
100mm(4") |
100mm(4") |
Cyclone Quantity |
4 |
8 |
10 |
16 |
Separation Particle Size |
20~40μm |
20~40μm |
20~40μm |
20~40μm |
Motor Power |
0.5 KW |
0.5 KW |
0.5 KW |
0.75 KW |
Applicable Field |
Wells less than 100 meters |
Horizontal Directional Drilling |
4000m oil drilling |
Oil drilling above 5000 meters |
Supporting Sand Pump |
SB4x3-15KW |
SB5x4-22KW |
SB8x6-55KW |
SB8x6-55KW |
Weight |
550KG |
750KG |
800KG |
1100KG |
Dimension: LxWxH |
1500x800x1800 mm |
1500x1200x1800 mm |
1500x1300x1800 mm |
1500x1500x1800 mm |
Desilter Cleaner Maintenance >>Send an Enquiry sales@hlsolidscontrol.com<<
1. The screen box locking bolts must be removed before the first use of the newly purchased desilter cleaner or the first use after moving.
2. When the cyclone is out of service for a long time, it must be cleaned with clean water circulation to prevent dry sand from accumulating in the cyclone.
3. Grease the vibration motor every 1500~2500 hours, and the amount of oil for each bearing is 5~10ml.
4. The screen should be cleaned after the machine is shut down to prevent the sand from becoming dry and unusable next time.